Next: Total systematic error calculations
Up: Systematic errors from ``split
Previous: and split samples
For the , we are able to check split samples of the following quantities:
- Particle/anti-particle
- Pre/post Target Silicon runs
-
- momentum
- mass36
The split sample fitted values for the are shown in
sc_mass:scp_splits. Although the fitted values do vary substantially,
none of the effects studied pass the requirement of being statistically
significant variations since the statistical error on the mass difference is
quite large.
Figure 6.12:
Summary of split
sample systematic errors. The solid and dashed lines are the
measurement and statistical errors. Points 1 & 2 are for particle and
antiparticle separately. Points 3 & 4 are for runs less than and greater than 9750.
Points 5 & 6 split the sample at
.
Points 7 & 8 split the sample
in momentum at 55 . Points 9 & 10 split the sample in mass for
each run.
sc_mass:scp_splits |
Eric Vaandering